Vacuum furnace with gas cooling under pressure of 15 BAR and vacuum nitriding option LPN TYPE 15.0 VPT-4035/36LPN
General Information:
/ Vacuum furnace with gas cooling under a pressure of 15 bar with vacuum nitriding function
/ Manufacturer SECO/WARWICK
/ Year of production 2015
/ Location – Northern Poland
/ The condition of the furnace was checked by the manufacturer in June 2025 – available report
/ Along with the furnace, a complete cooling system with a fan cooler, nitrogen buffer tank, and loading trolley!
/ The furnace has not been used, except for initial startup!
/ We offer relocation and installation of the device at the destination!
Technical Data
Working zone – Useful dimensions (W x H x L) | 600 x 600 x 900 mm |
Maximum load gross weight | 800 kg |
Temperature | |
Nominal temperature | 1300°C |
Temperature uniformity: | |
– from 150°C up to 750°C in convection gas ± 5°C | |
– from 600°C up to 1150°C in vacuum ± 5°C | |
Vacuum | |
Operating vacuum | 5×10-2 mbar |
Ultimate vacuum (clean, dry, outgassed, cold and empty furnace) | 1×10-2 mbar |
Leak rate (clean, dry, outgassed, cold and empty furnace) | <3×10-3 mbar_l/s |
Partial pressure control range | 10-1 ÷ 10 mbar |
Hot zone | |
Structure material mild steel | |
Thermal insulation 40 mm thick CFC-faced hard felt graphite boards backed by 10 mm thick soft graphite | |
Heating system | |
Heating elements low-voltage graphite bands | |
Heating elements distribution all around workload | |
Heating power | 150 kW |
Number of heating control zones | 1 |
Heating power control mode variable frequency drive | |
Convection heating | |
Convection atmosphere (gas / pressure) | Nitrogen / 1÷3 bar abs. |
Convection fan | 2,2 kW |
Motor control mode variable frequency drive | |
Vacuum pumping system | |
Rough vacuum pump SV300 Oerlikon Leybold | nominal pumping speed 280 m3/h |
Root’s pump WH700 Oerlikon Leybold | nominal pumping speed 1500 m3/h |
Furnace vessel | |
Material mild | steel |
Volume | 5,5 m3 |
Door locking mechanism Third clamping ring operated by electrical linear motor | |
Gas cooling system | |
Quenching gas nitrogen | |
Max. quenching pressure | 15 bar abs. |
Blower motor 2SKPW250-2A | |
motor power S2=180 kW; S1=110 kW | |
control mode variable frequency drive | |
Cool gas inflow nozzles all around the load and front door | |
Hot gas outflow window in rear wall | |
Instrumentation | |
Control and over-temperature thermocouples | 1 off, double, type S |
Load thermocouples | 2 off, type N |
Fine vacuum transmitter | TTR-91S / Oerlikon Leybold |
High vacuum transmitter (OPTIONAL) | PTR-90 / Oerlikon Leybold |
Control system | |
PLC S7-1500 / Siemens | |
Operator’s interface | Siemens TP1500 |
15” Touch screen | |
Over temperature controller | 3216i Eurotherm |
Variable frequency drives Danfoss |